At a glance
Key specifications
Precision visual reference
Dimensions and working range
Published measurements for the stated configuration. Illustration not to scale.

Overall Size
Working Range
Reference details
Visual visual:model-family:sennebogen:840-e:depth · revision 1 · generated 2026-09-08
Documented model generation; decorative reference illustration · Manufacturer-documented stationary installation, Lyon France
Canonical reference: heavyeq.ca/specs/material-handlers/sennebogen/840-e/ · Printed from HeavyEQ.ca. Confirm the actual machine and current manufacturer documentation before transport or operation.
Dimension verification
First-party confirmation exception list
Overall installation length
No project-matched installation plan dimension in the manufacturer case study.
840 E electric material handler installed on a fixed dock pedestal at Lyon, as identified in the manufacturer case study. Foundation, pedestal and working equipment are project-specific. · checked 2026-09-08Overall installation width
Pedestal and foundation footprint are project-specific and not published.
840 E electric material handler installed on a fixed dock pedestal at Lyon, as identified in the manufacturer case study. Foundation, pedestal and working equipment are project-specific. · checked 2026-09-08Overall installation height
No exact pedestal/cab/boom height package is published.
840 E electric material handler installed on a fixed dock pedestal at Lyon, as identified in the manufacturer case study. Foundation, pedestal and working equipment are project-specific. · checked 2026-09-08Loading height
Installed working diagram required; model-family reach does not establish loading height.
840 E electric material handler installed on a fixed dock pedestal at Lyon, as identified in the manufacturer case study. Foundation, pedestal and working equipment are project-specific. · checked 2026-09-08Year, generation & configuration
Model generation and configuration
- Generation / series
- 840 E stationary electric port installation, manufacturer Lyon case study July2023
- Applicable region
- Manufacturer-documented stationary installation, Lyon France
- Year handling
- Confirm the serial/PIN and production year when matching an individual machine to this reference.
Model identity
Model family, generation & status
- Model family
- Sennebogen 840 E
- Generation / record
- 840 E stationary electric port installation, manufacturer Lyon case study July2023
- Product status
- Production status not confirmed — status checked September 2026
- Regional scope
- Manufacturer-documented stationary installation, Lyon France
No verified lineage relationship published. HeavyEQ reviewed first-party sources and did not force a predecessor or successor from model numbering.
Manufacturer-documented stationary installation, Lyon France
Verified specifications
Values retain their cited source, verification status and original publication basis. Imperial is presented first while manufacturer-published dual units and configuration context remain attached to every value.| Specification | Imperial | Metric | Standard / configuration | Source |
|---|---|---|---|---|
| Reach — up to | 65 ft 7.4 in | 20,000 mm | Manufacturer840 E model-family upper reach shown alongside the case study; exact installed Lyon boom reach is not separately specified.Manufacturer verifiedSafety-sensitive value — verify the exact machine. | Sennebogen |
What the specifications mean
The manufacturer confirms a stationary dock installation supplied from the facility grid. Mobile chassis dimensions are not suitable substitutes for that installation.
The model-family reach is an upper capability reference, not proof of the installed boom or capacity at that reach. Obtain the project load and coverage diagrams.
Configuration intelligence
Configurations & specification differences
These observations are scoped to the cited generation and region. They are not a list of valid option combinations.
| Record | Verified observation | Scope |
|---|---|---|
| Reference configuration | 840 E electric material handler installed on a fixed dock pedestal at Lyon, as identified in the manufacturer case study. Foundation, pedestal and working equipment are project-specific. | 840 E stationary electric port installation, manufacturer Lyon case study July2023Manufacturer-documented stationary installation, Lyon France |
A brochure configuration is not an individual marketplace machine. Serial/PIN and build information are required for exact verification.
Used 840 E inspection priorities
- Request foundation loads, pedestal drawings, electrical supply requirements and the exact equipment/load chart before assessing a relocation or purchase.
- Have qualified specialists review structure, slew system, boom, grab, cab access and electrical protection, including the history of installation modifications.
Configuration-aware inspection: these checks are triggered by machine category, installed configuration and technology package. Brochure-listed technology must be physically present, active, licensed and calibrated on the used machine.
Hours, condition and ownership cost
Hours are context, not a condition grade. Duty cycle, idle time, maintenance evidence, wear-system measurements, structural repairs and installed technology should be evaluated together.
Cost drivers to model
- Compare the whole installed system: civil works, grid connection, material transfer points and maintenance access. Machine purchase price alone cannot represent project cost.
- Use actual duty cycle and energy tariffs for a cost scenario. Do not transfer the 855 E hybrid-system claims in the same story to this 840 E.
Configuration
Equipment and configuration
Match the installed equipment to the serial-specific build record and the measurement basis shown above.
Configuration details to confirm
- Application
- Electric or diesel
- Cab elevation
- Grapple or magnet
A model specification does not establish compatibility with a particular attachment or option.
Model-reference transport profile
Transport reference
Reference measurements retain their configuration and verification status. Confirm the actual transport setup before booking.
No transport-prefill values published for this record. Measure and weigh the configured machine.
Reference specifications can differ from the actual configured machine. Confirm dimensions and weight before booking transportation.
Confirm or replace before a transport request
- actual weight
- actual travel length, width and height
- attachments and removable work tools
- bucket, blade, carriage or boom position
- loading condition
Source provenance
First-party sources and verification notes
Only manufacturer-authored records are linked publicly. Provisional measurements remain marked until a matching first-party record is confirmed.840 E stationary electric port installation, manufacturer Lyon case study July2023
Manufacturer-documented stationary installation, Lyon France · exact model technical page · accessed September 8, 2026 · status: Manufacturer verified
