Manufacturer series profile

Bosch Rexroth BODAS RC series 40

Bosch Rexroth's BODAS RC series 40 is a named mobile-controller platform, useful for researching the difference between hardware capability and a machine application. Treat the family reference as a way to organize an identification inquiry. It does not identify the controller on a particular machine or establish that two coded units can exchange software, parameters, harnesses or safety responsibilities.

Series referenceInstalled fitment requires evidence
Research actions

At a glance

Selected reference specifications

These facts retain their item or series scope. They do not verify an installed application.

Documented specifications

Engineering specification reference

A concise reference to accepted facts. Expand a row for its exact configuration, locator and source evidence.

Bosch Rexroth BODAS hardware / RC series 40

Bosch Rexroth BODAS hardware / RC series 40: values and evidence scope
ParameterDocumented referenceEvidence
Manufacturer platformBODAS RC series40Bosch Rexroth public controller-family reference
Scope & source

Named controller family, not a verified installed assembly.

Bosch Rexroth public controller-family reference

Controllers

Basis: Named controller family, not a verified installed assembly.; conditions: Named controller family, not a verified installed assembly.

Public source reviewed 2026-10-15; document issue not stated

Bosch Rexroth BODAS hardware / RC series 40 ↗
Diagnostic-interface referenceUDSFamily interface statement; exact coded variant and application unknown
Scope & source

Interface availability does not establish permitted service functions or machine compatibility.

Family interface statement; exact coded variant and application unknown

Controllers

Basis: Interface availability does not establish permitted service functions or machine compatibility.; conditions: Interface availability does not establish permitted service functions or machine compatibility.

Public source reviewed 2026-10-15; document issue not stated

Bosch Rexroth BODAS hardware / RC series 40 ↗
Hardware-security referenceHardware security moduleManufacturer platform statement; no security implementation details supplied
Scope & source

A security feature is not a key/programming entitlement.

Manufacturer platform statement; no security implementation details supplied

Controllers

Basis: A security feature is not a key/programming entitlement.; conditions: A security feature is not a key/programming entitlement.

Public source reviewed 2026-10-15; document issue not stated

Bosch Rexroth BODAS hardware / RC series 40 ↗

BODAS Controller RC5-6 series 40

BODAS Controller RC5-6 series 40: values and evidence scope
ParameterDocumented referenceEvidence
RC5-6/40 power-output channel architecture11 power outputs, including 5 current-controlled channelsBODAS RC5-6/40; Series40; RE95207/2023-07-04
Scope & source

Published RC5-6/40 power-output architecture; subset, not additive count; no machine channel allocation

BODAS RC5-6/40; Series40; RE95207/2023-07-04

Printed p.1 Main components; p.2 Ordering code; p.3 Description

Published RC5-6/40 power-output architecture; subset, not additive count; no machine channel allocation — MANUFACTURER_COMPONENT_REFERENCE_ONLY; installed machine/PIN, harness, application and exact fitment NOT_ESTABLISHED

RE 95207/2023-07-04; replaces 2022-04-21

Manufacturer reference only. No installed machine, approved replacement or serial-specific fitment established.

BODAS Controller RC5-6 series 40 ↗
RC5-6/40 normal-mode supply range11–32 V DCBODAS RC5-6/40; Normal operation state only
Scope & source

Normal operation mode, ECU fully operational; distinct from12/24 V nominal battery and restricted neighboring states; not a service setting

BODAS RC5-6/40; Normal operation state only

Printed p.5 Technical data, Supply Voltage

Normal operation mode, ECU fully operational; distinct from12/24 V nominal battery and restricted neighboring states; not a service setting — MANUFACTURER_COMPONENT_REFERENCE_ONLY; installed machine/PIN, harness, application and exact fitment NOT_ESTABLISHED

RE 95207/2023-07-04; replaces 2022-04-21

Manufacturer reference only. No installed machine, approved replacement or serial-specific fitment established.

BODAS Controller RC5-6 series 40 ↗

Assembly intelligence

Know what the reference includes

Read the manufacturer-family scope accurately

The current BODAS overview lists CAN-related interfaces, UDS and a hardware security module for the controller platform. HeavyEQ interpretation: these are available family capabilities, not a complete specification for an unidentified coded unit. Preserve the full hardware label and revision when researching a particular controller. A machine manufacturer's module description may use another assembly identity or application name; retain those namespaces separately until a source establishes their relationship. This reference creates neither an exact service part nor a model-to-controller installation edge.

Separate platform software from the machine application

A programmable controller platform still needs an identified firmware/platform release, application and parameter set for its actual role. Record those as separate objects with authorized provenance. A matched hardware label cannot show which machine logic is loaded, which inputs and outputs are allocated or which calibration applies. Keep original factory documentation, current observed configuration and approved changes as separate events. An apparently newer programme or hardware revision is not automatically a valid successor, and a successful communication response is narrower evidence than correct execution of an actual machine application.

Distinguish current features, future variants and options

The overview describes Ethernet as a future variant. Do not convert that wording into a current universal RC40 feature. HeavyEQ comparison method: for every proposed interface, identify the actual coded variant and current applicable document before accepting it. Preserve optional hardware, connector configuration and application-dependent functions separately. A reference-family feature list should help locate missing documentation rather than supplying values for an unknown unit. Where two source issues disagree, keep the affected capability held instead of selecting the more attractive specification.

Variants & relationship boundaries

The original research below retains subject-specific variants, revisions and unresolved replacement questions. A shared series name, nominal dimension or supplier cross-reference does not establish interchangeability.

How directional replacement evidence works →

Application evidence

Research identity is separate from installed fitment

Accepted research scope
Manufacturer series profile
Serial-specific installation
Not established
Before ordering
Confirm the actual assembly, configuration, applicable manufacturer evidence and serial/build restrictions.

Model names, physical resemblance, dimensions and seller-reported associations cannot replace that evidence. No universal interchangeability is implied.

Identification workflow

Build a useful identification record

  1. Record the actual machine and installed component identities separately; keep private PIN and serial information secure.
  2. Preserve the full component maker, issued code, revision and supplied assembly scope.
  3. Use the identification fields and original research below to resolve configuration, interfaces and documented limits.
  4. Ask a qualified source to confirm the exact application and serial/build restrictions before ordering or installation.

What these specifications mean

Each documented value retains its named subject, parameter, configuration and source. A catalogue range or educational example is not a measurement of the installed component. Unestablished values remain open identification requirements.

Full reference library

Detailed research & identification evidence

The original technical record, source-qualified facts and unresolved questions remain below.

Bosch Rexroth's BODAS RC series 40 is a named mobile-controller platform, useful for researching the difference between hardware capability and a machine application. Treat the family reference as a way to organize an identification inquiry. It does not identify the controller on a particular machine or establish that two coded units can exchange software, parameters, harnesses or safety responsibilities.

Start with the exact research subject

Retain the component issuer and complete observed identifier. Distinguish a general family reference from a coded variant, the currently installed assembly and its machine application.

Read evidence at its stated level

The detailed original research below retains source scope, native units and the conditions actually established. An unavailable measurement remains unknown; general model or technology references do not certify a replacement.

Follow the installation evidence

Use applicable manufacturer and machine documentation to resolve hardware, electrical, signal, harness, software and safety requirements. Keep individual machine identifiers and service credentials private.

Source references

Original research commentary. Manufacturer drawings, catalogue tables and inventory are not reproduced.

Technical research & specification evidence

BODAS RC series 40: controller hardware and application boundaries

Manufacturer product-series reference; exact issued variant, machine installation and application compatibility not established

Read the manufacturer-family scope accurately

The current BODAS overview lists CAN-related interfaces, UDS and a hardware security module for the controller platform. HeavyEQ interpretation: these are available family capabilities, not a complete specification for an unidentified coded unit. Preserve the full hardware label and revision when researching a particular controller. A machine manufacturer's module description may use another assembly identity or application name; retain those namespaces separately until a source establishes their relationship. This reference creates neither an exact service part nor a model-to-controller installation edge.

Separate platform software from the machine application

A programmable controller platform still needs an identified firmware/platform release, application and parameter set for its actual role. Record those as separate objects with authorized provenance. A matched hardware label cannot show which machine logic is loaded, which inputs and outputs are allocated or which calibration applies. Keep original factory documentation, current observed configuration and approved changes as separate events. An apparently newer programme or hardware revision is not automatically a valid successor, and a successful communication response is narrower evidence than correct execution of an actual machine application.

Distinguish current features, future variants and options

The overview describes Ethernet as a future variant. Do not convert that wording into a current universal RC40 feature. HeavyEQ comparison method: for every proposed interface, identify the actual coded variant and current applicable document before accepting it. Preserve optional hardware, connector configuration and application-dependent functions separately. A reference-family feature list should help locate missing documentation rather than supplying values for an unknown unit. Where two source issues disagree, keep the affected capability held instead of selecting the more attractive specification.

Build the physical and electrical identification record

Request the exact product identity, hardware revision, supplied accessories and governing connection/environment documents. Distinguish the power-supply envelope from nominal voltage and any transient claims. Record channel types and the authorized application allocation rather than using a total I/O count as an interchange rule. Keep harness and mating-connector identities separately traceable. A matching enclosure or connector arrangement cannot establish signal functions or approval to reuse a field-made adapter. No terminal map, wiring directions or method for energizing unknown outputs is supplied by this public reference.

Keep safety documentation tied to the implementation

A manufacturer's safety-capability description needs its own coded-product conditions and supporting documents; it does not validate a complete machine repair. HeavyEQ evidence method: identify the actual safety function, connected devices, application, parameters and acceptance source separately from the controller-family record. The applicable standard edition and qualified system assessment remain controlled questions. Do not publish a machine performance-level badge from a family overview. A replaced sensor, harness or output device should remain a visible change rather than being hidden by an unchanged controller label.

Assess an offered unit without assuming installation

For used or reconditioned hardware, request removal reason, preservation history, work scope and a report identifying the actual tested unit and configuration. Distinguish hardware examination, communications assessment and complete-machine acceptance. Keep private identifiers, credentials and customer configuration data restricted. This research supplies no programming files, security keys, update recipe or bypass method. Exact machine fitment, software compatibility and safe application remain unresolved. The useful result is a scoped controller inquiry that preserves the boundary between named manufacturer platform, exact hardware, authorized software and the machine in which it would operate.

Read RC5-6/40 as a documented channel architecture

The exact RC5-6/40 reference gives a useful example of why a controller name needs its maker’s decoding context. RE 95207 identifies eleven power outputs, including five with current control. The designation therefore carries more information than an enclosure photograph or a generic description such as mobile ECU. It does not count every signal connection or identify eleven independent machine functions. For a comparison record, keep the issued designation beside separate entries for input classes, power-output classes and communication interfaces. Preserve the document’s own channel categories so a seller’s combined I/O total cannot obscure the distinction.

Normal supply state has its own boundary

Bosch lists nominal battery systems of 12 V and 24 V, while its normal-operation envelope for this controller is 11–32 V. Those are different statements: the former identifies the intended battery architecture and the latter describes a particular operating state. Adjacent ranges in the same document carry restrictions, so a broad minimum-to-maximum headline would lose useful information. An identification enquiry should ask which supply statement a quoted number represents and retain the document edition with it. These values characterize the RC5-6/40 reference, without prescribing a test voltage or a setting for an installed machine.

A comparison record needs positive and unresolved entries

A useful comparison can record the two established facts while leaving the actual machine’s channel allocation blank. Add the accessible material identity, revision markings and evidence connecting the offered controller to the authorized application. Treat a missing application record as a separate unresolved item; do not fill it by matching the numeric designation. Record the provenance of a used module’s label alongside any conflicting seller description, keeping both observations available for qualified review. Comparison should stop at the documented hardware boundary until the machine authority resolves software state, harness and acceptance. This preserves the existing controller guide’s scope while adding a concrete manufacturer example.

Specification evidence record

Published values retain their exact reference scope. Empty fields mean the value has not been established; they never mean zero. General model associations do not establish installed or serial-specific fitment.

BODAS RC series 40: controller hardware and application boundaries: documented values and open identification fields
PropertyValue / statusScope and interpretation
Manufacturer platformBODAS RC series40 Named controller family, not a verified installed assembly.

Reference: Bosch Rexroth public controller-family reference

Basis: Named controller family, not a verified installed assembly.; conditions: Named controller family, not a verified installed assembly.

Bosch Rexroth BODAS hardware / RC series 40 ↗ · Controllers

Public source reviewed 2026-10-15; document issue not stated

Diagnostic-interface referenceUDS Interface availability does not establish permitted service functions or machine compatibility.

Reference: Family interface statement; exact coded variant and application unknown

Basis: Interface availability does not establish permitted service functions or machine compatibility.; conditions: Interface availability does not establish permitted service functions or machine compatibility.

Bosch Rexroth BODAS hardware / RC series 40 ↗ · Controllers

Public source reviewed 2026-10-15; document issue not stated

Hardware-security referenceHardware security module A security feature is not a key/programming entitlement.

Reference: Manufacturer platform statement; no security implementation details supplied

Basis: A security feature is not a key/programming entitlement.; conditions: A security feature is not a key/programming entitlement.

Bosch Rexroth BODAS hardware / RC series 40 ↗ · Controllers

Public source reviewed 2026-10-15; document issue not stated

Ethernet capabilityUnavailablePublic overview calls it future; exact current coded support not accepted.

Reference: Actual installed hardware/software/harness and machine application unresolved

Bosch Rexroth BODAS hardware / RC series 40 ↗ · Future variants sentence

Installed application/safety/harnessUnverifiedRequire exact variant, authorized application and system assessment; no installation verified.

Reference: Actual installed hardware/software/harness and machine application unresolved

RC5-6/40 power-output channel architecture11 power outputs, including 5 current-controlled channels Published RC5-6/40 power-output architecture; subset, not additive count; no machine channel allocation

Reference: BODAS RC5-6/40; Series40; RE95207/2023-07-04

Published RC5-6/40 power-output architecture; subset, not additive count; no machine channel allocation — MANUFACTURER_COMPONENT_REFERENCE_ONLY; installed machine/PIN, harness, application and exact fitment NOT_ESTABLISHED

BODAS Controller RC5-6 series 40 ↗ · Printed p.1 Main components; p.2 Ordering code; p.3 Description

RE 95207/2023-07-04; replaces 2022-04-21

Manufacturer reference only. No installed machine, approved replacement or serial-specific fitment established.

RC5-6/40 normal-mode supply range11–32 V DCNormal operation mode, ECU fully operational; distinct from12/24 V nominal battery and restricted neighboring states; not a service setting

Reference: BODAS RC5-6/40; Normal operation state only

Normal operation mode, ECU fully operational; distinct from12/24 V nominal battery and restricted neighboring states; not a service setting — MANUFACTURER_COMPONENT_REFERENCE_ONLY; installed machine/PIN, harness, application and exact fitment NOT_ESTABLISHED

BODAS Controller RC5-6 series 40 ↗ · Printed p.5 Technical data, Supply Voltage

RE 95207/2023-07-04; replaces 2022-04-21

Manufacturer reference only. No installed machine, approved replacement or serial-specific fitment established.

Unresolved technical and source questions (3)
  • Exact hardware/order code, I/O allocation, supply/environment conditions and installed application unknown.
  • Ethernet future wording must not be promoted to current universal capability.
  • No machine safety certification or service/programming authorization inferred.

Research sources and scope

  • Bosch Rexroth BODAS hardware / RC series 40 ↗ · first party public reference · checked 2026-10-15

    Controllers, Functional safety and Connectivity devices; Ethernet expressly future variants; no exact RC40 coded unit identified

    Original limited factual reference only; no software, standards clauses, pinouts, catalogue/table, diagrams or media redistribution licence supplied

  • BODAS Controller RC5-6 series 40 ↗ · first party technical reference · checked 2026-10-17

    Printed pp.1–3,5; Main components, Ordering code, Description, Technical data

    Selected attributed factual reference and independently authored HeavyEQ analysis only. No catalogue, table, image, diagram, manual, software, inventory or service-text redistribution licence established.

Original HeavyEQ analysis and selected source facts. No catalogue reproduction licence, manufacturer endorsement or machine-specific compatibility is implied.